LIBS和Raman分光学组合:海水调查领域盐分检测方法.
Combined LIBS and Raman spectroscopy: an approach for salinity detection in the field of seawater investigation.
作者
Authors
Fan Yansheng, Xue Yuanyuan, Wang Yiping, Liu Runze, Zhong Shilei
期刊
Journal
暂无期刊信息
年份
Year
2026
分类
Category
国家
Country
-
DOI
10.1364/AO.451169
📝 摘要
Abstract
As salinity is an important indicator in marine geology, ecology, breeding, and other fields, accurate, rapid, and continuous measurement of salinity is of great significance in marine investigations. At present, the seawater salinity detection methods used in practice are mainly based on the principle that the conductivity and refractive index parameters of the water change with the concentration of elements, which are composed of salinity change. However, these methods quantitatively analyze salinity values by measuring other parameters (electrical or optical parameters) that may change depending on the salinity of the water, rather than the mass fraction of the components that make up the salinity. Moreover, when the salinity value of seawater water changes substantially or the proportion of various common components composing salinity changes significantly, the detection accuracy of the above methods is difficult to guarantee. Therefore, a spectral approach, LIBS, and the Raman spectroscopy combination method for salinity analyzation, LRSS, were proposed to provide a new option. The main idea of this approach is to use the two spectral detection methods, LIBS and Raman, to determine the mole values of cations and non-monatomic anions in per unit quality (1 kg) of water, respectively. Then the mole value of the chloride ion, which is the main monatomic anion in seawater, can be determined according to the electrically neutral principle. Based on all the obtained molar values and the molar mass of each ion, the salinity of the water sample can be determined. To demonstrate the performance of this new method, we compared it with LIBS under laboratory conditions and found that, when non-monatomic anions are present in the water, the accuracy of LRSS is significantly improved compared to using the LIBS method alone. Moreover, we also compared the LRSS with the other two traditional methods through the 11 water samples configured and found that the absolute value relative error of the LRSS is only 2.63% when the salinity and components concentration change is in the possible range, which is better than the conductivity method 0.53 times and better than the refractive index method 1.52 times.
📊 文章统计
Article Statistics
基础数据
Basic Stats
47
浏览
Views
0
下载
Downloads
10
引用
Citations
引用趋势
Citation Trend
阅读国家分布
Country Distribution
阅读机构分布
Institution Distribution
月度浏览趋势
Monthly Views